Finally the E/E’ index was determined Echocardiographic analysis

Finally the E/E’ index was determined. Echocardiographic analysis was performed by two independent reviewers, blinded to the clinical data, using dedicated computer software (EchoPAC, version 110.0.0, GE Medical, Milwaukee,

WI, USA). Cardiac magnetic resonance imaging All patients underwent a CMR study at baseline and at 12 months following initiation of NHD. All CMR studies were performed using a 1.5-T Siemens Scanner (Magnetom Sonata, Siemens Medical Systems, Erlangen, Germany). Cardiac parameters of interest included chamber dimensions, volumes, and systolic function which were analyzed in accordance with guidelines of the Society for https://www.selleckchem.com/products/Trichostatin-A.html Cardiovascular Magnetic Resonance [17]. PARP inhibitor End-systolic and end-diastolic volumes of the left and right ventricle were obtained using manual tracing of ventricular walls in multiple short axis slices. End diastole was defined as the slice in which the ventricle was at its largest volume, while end systole was defined as the slice with the smallest volume. Stroke volume (SV) was calculated as the difference between the end-diastolic volume (EDV) and end-systolic

volume (ESV). Left and right ventricular mass were determined using the find more summation of slices method [18]. Endocardial and epicardial borders of the left and right ventricle, excluding papillary muscles, were manually traced in each image slice used to calculate EDV and ESV. Myocardial volume isometheptene was calculated by multiplying these values by slice thickness. Myocardial mass was then determined by multiplying each volume by 1.05 g/cm3. Analysis of CMRs was conducted by two independent reviewers, blinded to the clinical data, using dedicated computer software (CMR42, version 1.0.0, Circle

Cardiovascular Imaging, Calgary, AB, Canada). Statistical analysis All parametric data were reported as mean ± standard deviation (SD). Categorical data were reported as “n” (percentage). The Mann–Whitney U test was used to measure the intra- and inter-observer variability for LV end-diastolic volume and LV mass for both imaging modalities. Statistical significance was defined as p < 0.05. SAS version 8.01 (SAS Institute Inc., Cary, North Carolina) was used to perform the analysis. Results Study population A total of 11 patients (mean age 48 ± 16 years) were enrolled in the study, of which 6 were male (Table 1). Ten patients underwent conventional, thrice-weekly facility-based hemodialysis at baseline (prior to enrollment), while one patient performed home peritoneal dialysis. The most frequent etiology of kidney failure was glomerulonephritis (55 %), followed by diabetic nephropathy (18 %) and polycystic kidney disease (18 %). Cardiac comorbidities included hypertension (63 %), ischemic heart disease (27 %), diabetes mellitus (36 %), and valvular heart disease (9 %).

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>